주식회사 에이치시티

Contact us
 

Cleanroom consignment management

Clean room

Upcoming cleanroom performance evaluation,
It needs to be prepared with professional management.

As industrial technology becomes more highly integrated, human resources, environment, equipment, raw materials, utilities, etc. that are directly or indirectly involved in production
It is necessary to maintain optimal conditions to meet the appropriate standards. It is necessary to manage and control airborne particles.
Autonomous quality management for the clean room for the purpose of improving production yield and strengthening technological competitiveness,
External quality assurance is also guaranteed. Group quality certification by the Korea Air Cleaning Association.
With the implementation of the Cleanroom Performance Evaluation imminent, is your cleanroom environment being properly managed?

Service Procedure

Performance Evaluation Process
Step 1

receipt

  • Request for a third-party clean room company
  • Request for performance evaluation of manufactured products
  • Request for regular Clean Room evaluation
Step 2

On-site verification

  • Clean Room Detailed Location and Brief Map
  • Clean Room Design Conditions
  • Check out the product and review locations
Step 3

Performance Evaluation

  • Particle / Temperature and humidity / Differential pressure
  • Addition of items upon customer request
Step 4

Issuance of transcripts

  • Preparation and issuance of test report upon acceptance
  • Suggestions for environmental improvement points

Service items

Cleanroom solutions and
Technical capabilities
01
Optimizing the cleanroom environment
  • Room environment measurement and patrol inspection
  • Issue-related response
  • On-site verification of abnormal occurrences
  • Identifying root causes through 3D airflow analysis
C/R traversal verification
Online Monitoring
 
AMC Control
Environmental verification
02
Ensuring core equipment performance
  • Equipment Internal FFU and Environmental Verification (T.A.B)
  • Real-time environmental monitoring during equipment operation
  • Ionizer / Precise evaluation of static electricity levels
Mini Environment
Wafer exposure environment verification
 
Prevent ESD particle adsorption
P/Counter & S/Com
03
FMS
  • Building and maintaining a stable FMS system
  • Regular assessment of the reliability of measuring equipment
  • Immediate emergency response when an FMS issue occurs
System Management
Real-time analysis
Comprehensive Environmental Assessment
P/Counter & S/Com
04
Ionizer and static electricity management
  • Controlling electrostatic contamination from an ESDA perspective
  • Precise evaluation and improvement of ionizer performance
  • Static Control and Testing
Ionizer Performance Evaluation
Prevent ESD particle adsorption
 
Room/Equipment Environment Assessment
05
Micropollution Assessment and Analysis
  • Building and maintaining a stable FMS system
  • Regular assessment of the reliability of measuring equipment
  • Immediate emergency response when an FMS issue occurs
System Management
Real-time analysis
Comprehensive Environmental Assessment
P/Counter & S/Com
Detailed technical services
01

Clean room environment

Online Monitoring

  • Real-time analysis and system management

T.A.B

  • Comprehensive Environmental Assessment

C/R traversal verification

  • Environmental verification
02

Equipment internal environment

Mini Environment

  • Wafer exposure environment verification
    - P/Counter & S/Com

Ionizer Performance Evaluation

  • Prevent ESD particle adsorption
    - Room / Equipment
03

Utility Quality

DIW Quality

  • Ultrapure water quality verification
    - 18M DIW Monitoring

Chemical Metal Trend

  • Metal concentration assessment
    - DIW / H2O2 / NH4OH
04

ECCB

Workmanship Audit

  • Change point Control and workers, construction, etc.
    Issue

Environmental assessment

  • Change Area Environmental Pollution Assessment
Technical capabilities
01

3D airflow analysis and CFD simulation

Prevent the spread of contaminants and maintain optimal air conditioning system efficiency by accurately identifying points where airflow stagnates or vortices occur within a cleanroom.

3D airflow analysis equipment

With the most advanced 3D ultrasonic anemometer
Precisely measure the airflow on site.

CFD simulation

Through computational fluid dynamics (CFD) simulation
May occur when changing equipment layout or new construction
Predict and prepare for air current changes in advance.

02

Particle and air pollution component analysis

Beyond measuring pollution levels, we precisely analyze the components of pollutants to trace the source of pollution and suggest fundamental solutions.

BIO GMP
Cleanliness grade ISO grade number floating bacteria parasitic bacteria Surface fungi (equipment)
A 5 < 1 < 1 < 1
B 6 ≤ 10 ≤ 5 ≤ 5
C 7 ≤ 100 ≤ 50 ≤ 25
D 8 ≤ 200 ≤ 100 ≤ 50
BIO Clean Room
Microbiological evaluation

Key sampling and analysis items

wealthy group
Using a collector
parasitic bacteria
Neglect assessment
Surface fungi
Direct capture
incubator
Microbial culture
microorganism
evaluation
Visual confirmation
counsel TOP